Pressure delivery | 1 – 65 mbar +-(4% + 2mbar) |
Volume delivery | 200 – 2000 ml +-(15% + 4ml) |
Oxygen delivery | 21 – 100 % +-(2.5% + 2.5vol%) |
Pressure monitoring | +-(4% + 2mbar) |
Volume monitoring | +-(15% + 4ml) |
Oxygen monitoring | +-(2.5% + 2.5vol%) |
Pressure Controlled Ventilation (PC)
Pressure Regulated Volume Controlled Ventilation (PRVC)
Pressure Support Ventilation (PS)
Continuous Positive Airway Pressure Ventilation (CPAP)
This provides critical care solutions and respiratory therapies for the ICU, as well as invasive and non-invasive breathing assistance for adult and pediatric patients.
Pressure delivery | 1 – 65 mbar +-(4% + 2mbar) |
Volume delivery | 200 – 2000 ml +-(15% + 4ml) |
Oxygen delivery | 21 – 100 % +-(2.5% + 2.5vol%) |
Pressure monitoring | +-(4% + 2mbar) |
Volume monitoring | +-(15% + 4ml) |
Oxygen monitoring | +-(2.5% + 2.5vol%) |
RR | 2-40 bpm |
I:E | 1:4-4:1 |
Vt | 300-2000 mL |
Psafety | 2-65 hPa |
DPinsp | 1-60 hPa |
PEEP | 1-40 hPa |
Ps | 0-64 hPa |
FiO2 | 21-100 vol.% |
Insp Fl trigg | 0-10000 mL/min. |
Exp. Fl.cycl perc. | 0-100 % of Peak flow. |
Main device | 32cm x 38 cm x 20 cm (l*w* h) |
Setting | Min | Max | Unit | Default Minimum Value | Default Maximum Value | |
1 | PEEP | 0 | 56 | mbar | 75% of confirmed setting | 125% of confirmed setting |
2 | 300-2000 mL | 1 | 65 | mbar | 75% of confirmed setting | 125% of confirmed setting |
3 | PC above PEEP | 0 | 20000 | mL/min | 75% of confirmed setting | 125% of confirmed setting |
4 | Vte | 200 | 1200 | ml | 75% of confirmed setting | 125% of confirmed setting |
5 | RR | 2 | 40 | bpm | 75% of confirmed setting | 125% of confirmed setting |
6 | FiO2 | 18 | 110 | % | 90% of confirmed setting | 110% of confirmed setting |
MV | 0-20000 | mL/min. |
Vt | 180-2000 | mL |
RR | 2-60 | bpm |
PEEP | 0-56 | hPa |
Pplat | 0-70 | hPa |
FiO2 | 18-103 | vol.% |
Pmin PRVC | 1-64 | hPa |
Pmax PRVC | 1-65 | hPa |
Description | Use | Comments | |
1 | Hose system | Single Use |
Any dual limb system, length between 0.7m and 2m, heated or not No antistatic or electrically conductive hoses. |
2 | Outlet filter | Single Use |
Any regular bacterial filter with standardized connections for breathing systems, compatible with NEN-EN-ISO 23328-1:2008 and NEN-EN-ISO 23328-2:2009 |
3 | HME filter | Single Use | Any regular HME filter with standardized connections for breathing systems |
4 | Patient flow sensor | Single Use | Contact the supplier through disposables@demcon.com |
5 | Hose connection | Single Use | Any hose connector |
6 | Expiration valve | Single Use | Contact the supplier through disposables@demcon.com |
7 |
Expiration valve pressure control hose |
Single Use | Any silicon pneumatic hose for expiration valve pressure control blue (external 120mm) |
8 | Machine air inlet filter | Single Use | Camfil 95300 |
9 | O2 sensor | Single Use | Any regular galvanic O2 cell using a screw connection, M16x1 |
10 | Bacteria virus filter | Single Use |